The RXS500 is a hipot tester which together with the FMG rack can perform leakage current measurement under nominal voltage, and power measurement for single phase equipment and three phase equipment.

Complies with:

EN61010-1, EN60065, EN61335-1, EN60950, EN60598-1, EN60601-1 standards

View the RXS500 hipot tester on the manufacturer's website

Related Products

Hipot / Dielectric Strength Testers

Customer Comments

No comments have been made about this product. Be the first to let us know what you think.

Knowledge Base

You must be registered to view Knowledge Base articles related to this product. Please register or log-in to view these articles.

Key Features

  • Dielectric strength tester from 0 to 5 kVAC and 0 to 6 kVDC (RXS56, RXS506 models)
  • 8 test step sequences
  • 50 parameter sets storage
  • Built in RS232C interface
  • ETHERNET, PLC or IEEE4882 interfaces on option

Downloads

Please feel free to download any of the documents associated with this product.

Technical Specification

DIELECTRIC STRENGTH TEST FUNCTION

Output voltage

  • 0 to 5 kV AC (50 or 60 Hz).
    Limited to 4.2 kV AC with FMG501
  • 0 to 6 kV DC (RXS56, RXS506)
  • Accuracy: ± (2%+50 V) (RXS50) and ± (3%+50 V) (RXS500) of the preset value between 100 to 5000 V and for a current < 100 μA (RXS50) and < 1 mA (RXS500) with the detection modes: DI, IMAX or DI+IMAX

Voltage reading

  • On a digital kilovoltmeter connected on the output terminals
  • Accuracy: ± (1.5% + 20 V)
  • Display: 600 digits

Stability

  • Less than 1% for a mains variation of ± 10% (RXS50)
  • Less than 3% for a mains variation of ± 10% (RXS500)

Current

  • Short circuit < 13 mA AC (RXS50/56) and < 9 mA DC (RXS56) for the max. voltage adjustment
  • Short circuit > 200 mA AC (RXS500/506) and >20 mA DC (RXS506) for the max voltage adjustment
  • Short circuit duration limited to 5 seconds
  • Nominal current : 10 mA AC (RXS50/56) and 4 mA DC (RXS56)
  • Nominal current : 10 mA DC (RXS506) and 110 mA AC (RXS500/506)

Current reading

  • On a shunt resistor inserted in the test circuit
  • Accuracy: ± (2.5% + 2U)
    1U = 0.01 mA (RXS50)
    1U = 0.1 mA (RXS500)
  • Display: 1000 digits

Breakdown detection

  • "DELTATEST" detector adjusted for DI = 1 mA ± 10% (RXS50) and DI = 10 mA
    ± 10% (RXS500) with 10 μsec. ± 20%.
    Total insensitivity to current due to the resistance and the capacitance of the device under test
  • "IMAX" detection by maximum current adjustable from 0.01 to 10 mA, by 0.01 mA steps (RXS50) and from 0.1 to 110 mA by 0.1 mA steps (RXS500)
  • DELTATEST and IMAX mode combination

IMIN threshold function

  • Detects whether the probe is properly
    connected to the specimen under test
  • Adjustable from 0.01 to 10 mA (RXS50) and from 0.1 to 110 mA (RXS500)

DC voltage (RXS56, RXS506 models)

  • Positive pole grounded
  • —Ripple < 1% for I < 100 μA (RXS56) and I < 1 mA (RXS506)

Breakdown indication

  • By visual (LCD screen and LED) and sound signal
  • Breakdown voltage and current are stored on the LCD display
  • HV primary transformer shorted when the output voltage is switched off

Timer

  • Rise, hold and fall time adjustment between 0 and 999 sec.
  • Fast mode : (rise + hold) < 900msec.

Storage

  • 10 test parameter (voltage, threshold, time,...) sets can be stored

GENERAL CHARACTERISTICS

Presentation

  • Table top unit
  • Metal case

Dimensions

  • Height : 131 mm
  • Width : 440 mm
  • Depth : 450 mm

Weight

  • 27 kg

Power

  • 230 V or 115 V ± 15% single phase, 4763 Hz
  • Consumption: 70 to 600 VA depending on test

Operating temperature

  • 0°C to +45°C

Storage temperature

  • 10°C to +60°C

Overvoltage category

  • CATII

Pollution degree

  • 2

Safety class

  • Class I (earth connection)

View full technical specification

Knowledge Base

Product Matrix

The Product Matrix allows you to compare the features of up to 5 products. Simply check the box next to the products you wish to compare then select the 'Compare Products' button.

Product Enquiry

Contact Information

indicates required field
Title*
Please type in the validation code from the image (case sensitive).

Additional Information (optional)

 
Site engineered by NorthBloc   
© 2010, Seaward Electronic Group Ltd. All rights reserved.